New continuous and pulse electronic personal dosimeters PM1610B / B-01 are specifically designed for personnel who are at risk of irradiating during professional activities.
PM1610B / B-01 is a special modification of PM1610 series personal dosimeters. The instrument is equipped with AAA (LR03) battery so it is ready to be used immediately after installing the battery. PM1610B / B-01 is distinguished by extended DE measurement range and advanced accuracy of DER measurement.
The instruments provide measurement of dose equivalent and dose equivalent rate of continuous and pulsed X-ray and gamma radiation, as well as time of dose accumulation.
Devices have audible, visual and vibration alarms to warn a user when preset dose/dose rate threshold levels are exceeded.
The PM1610B-01 version can be used with different types of wireless readers in compliance with ISO 15693.
Features
- Measurement of pulse X-ray and gamma radiation with pulse duration 1 ms and up
- Dose rate measurement up to 10 Sv/h (1000 rem/h)
- Dose measurement up to 20 Sv (2000 rem)
- Two independent alarm thresholds for dose and dose rate
- Wide energy range from 20 keV to 10 MeV
- Settings can be controlled (blocked by the user to change) from a PC via USB
- Ability to display measurements in Sv or rem
- Audible, visual and vibration alarms
- Turning off the alarm by pressing any button
- Shockproof hermetic case
- Light weight and compact size
The instruments can be integrated into Personal Dose Tracker System for having radiation measurements stored and for monitoring personnel exposure data.
Application
- Civil Defense
- Emergency services
- First responders
- Customs and border patrol
- Medical professionals
- Radiological and Radionuclide isotope laboratories
- Other professionals
|
PM1610B / B-01
|
Detector
|
Geiger-Mueller tube
|
Dose Rate display
|
Indication range
0.01 μSv/h - 12.0 Sv/h (1 μrem/h - 1200 rem/h)
Measurement range
0.1 μSv/h - 10.0 Sv/h (10 μrem/h - 1000 rem/h)
|
Dose Rate Accuracy
|
±(10 + 0.0015/H + 0.0015*H) %,
where H - DER value in mSv/h
|
Dose measurement
|
Indication range
0.001 μSv - 24.0 Sv (0.1 μrem - 2400 rem)
Measurement range
- continuous photon radiation (current)
0.05 μSv - 20.0 Sv (5 μrem - 2000 rem)
- pulsed photon radiation (pulse duration not less than 1 ms)
10 μSv - 20.0 Sv (1000 μrem - 2000 rem)
|
Dose Accuracy
|
± 20 %
in the range 0.05 μSv - 20.0 Sv
|
Energy range
|
20 keV - 10 MeV
|
Energy response relative to 0.662 MeV
(137Cs)
|
- 60% at 20 keV - 33 keV
- 40% at 33 keV - 48 keV
±30% at 48 keV - 3 MeV
±50% at 3 MeV - 10 MeV
|
Survive after momentary influence of maximum
permissible gamma radiation within 5 min:
|
Standards compliance
|
Alarm type:
|
Audio, visual, vibration
|
Physical Parameters
|
Dimensions
|
71х59х20 mm
|
Weight
|
90 g
|
Environmental Characteristics
|
Temperature
|
from -20 to +50°C
|
Humidity
|
Environmental protection
|
IP65
|
Drop test
|
Water resistant
|
Power
|
Batteries
|
Battery type LR03/AAA
|
Battery lifetime (average DER not more than 0.3 µSv/h,
alarms activated for not more than 20 s/24 hours)
|
no less than 30 days
|
Battery discharge control
|
Indication on LCD
|
Additional
|
Countdown timer
|
no
|
Display of time to critical exposure
|
no
|
Functions
|
no
|
Calendar mode
|
no
|
PC Communication
|
USB interface
ISO15693 interface for РМ1610B-01
|
|